МГП FS FireStop ECO module construction
- Cylinder
- Discharge valve (ЗПУ)
- Rubber seal
- Pressure indicator
- Ceiling bracket kit
- Label
- Bursting disc safety device

Actuation and pressure monitoring
Electromagnetic actuation
The solenoid receives an electrical pulse from the control unit. Supply: 24 ± 2 V; current: 1–1.5 A; maximum actuation delay: 2 s.
Autonomous version
This МГП FS version has a discharge valve with an integrated solenoid and an autonomous release device activated by temperature.
Equipment documentation
Scope of supply
| Item | Supply |
|---|---|
| Cylinder with discharge valve | Included |
| Rubber seal, pressure indicator and bursting disc safety device | Included |
| Ceiling bracket kit | Included |
| Operating manual with product datasheet | Included |
| Electromagnetic actuator with manual release | Ordered separately |

The actuator version and agent fill weight are specified in the order. The final scope of supply is recorded in the specification.
Operating principle and layout of a ceiling-mounted gaseous fire suppression system
- Ceiling-mounted FireStop module
- Smoke or heat fire detectors
- R3-Рубеж-2ОП addressable control panel
- Illuminated warning signs
- Manual release device
- Sounder
- МПТ-1 addressable module
- ИВЭПР — secondary power supply
- R3-ПДУ-ПТ multi-room control device

Fire detection
Addressable detectors (2) send signals to the R3-Рубеж-2ОП panel (3). Once the release conditions specified in the design and system settings are met, the panel sends a command over the addressable loop to the МПТ-1 suppression control module (7).
Warning and release delay
МПТ-1 activates the connected warning signs (4) and sounders (6), then counts down the configured gas release delay. The sequence accounts for the automatic operating mode and design interlocks, including door monitoring.
Suppression release
When the delay ends and release conditions are met, МПТ-1 (7) signals the actuators on the ceiling-mounted modules (1). The agent enters the room through the module nozzles.
Suppression and status monitoring
The gas spreads throughout the protected volume, establishing the extinguishing concentration. With the appropriate sensors connected, МПТ-1 monitors discharge using mass or pressure signals and reports events to the panel. System status and faults are displayed on R3-Рубеж-2ОП.
Benefits of ceiling-mounted module systems
«FireStop ECO»
Easy installation
No piping or welding required
Fire alarm integration
Compatible with systems from Рубеж, Bolid, Стрелец and other manufacturers
Lower operating costs
Cylinder inspection every 10 years reduces module maintenance costs
Recommended for protecting these facilities
Data centres and server rooms
Power stations and energy facilities
Bank vaults
Art galleries, museums and libraries
Electrical switchgear rooms and diesel generator sets
Modular containers
Document archives
How to order
Step 1 / Initial enquiry
Request a callback or contact us by phone or email
Step 2 / Consultation
We answer your questions and explain our products, model differences, applications, ordering and delivery terms
Step 3 / Calculation and equipment selection
Using your answers, our technical team calculates the required number of modules and selects the extinguishing agent
Step 4 / Quotation
Based on the calculation, our sales team prepares a quotation detailing equipment, delivery times, prices and special terms
Step 5 / Contract
Once all terms are agreed, we sign the contract
Step 6 / Dispatch and delivery
After receiving payment under the contract, we manufacture and dispatch the products and monitor delivery

Ceiling-mounted module datasheet
Cylinder datasheet
Cylinder datasheet
EAC certificate
EAC certificate